Number of control axes |
1 |
Reference clock (standard) |
19.6608MHz (max 30MHz) |
Maximum pulse output frequency |
9.8Mpps at 19.6608MHz (15Mpps at 30MHz) |
Number of speed setting registers |
2 (FL, FH) |
Number of steps to set/change the speed |
1 to 16,383 (14-bits) |
Speed multiplication rate range |
0.1 to 600x |
Acceleration range |
1 to 16,383 (14-bits) |
Deceleration rate range |
1 to 16,383 (14-bits) |
Number of positioning pulses |
-134,217,728 to +134,217,727 (28-bits) |
CPU Interface |
8/16-bit bus |
Ramping down point |
0 to 16,777,215 (24-bits) |
Package types |
80-pin QFP |
Power supply voltage |
+3.3V ±10% |
Automatic ramp-down point setting |
Yes |
Ramp-down point offset setting |
Yes |
Up/down counter (Current position counter) |
Yes (28-bits; provided for each axis) |
Other counters (Software zero position auto return) |
Yes |
External mechanical signal input (±EL ±SD ORG) |
Yes (provided for each axis) |
External mechanical start signal for a Hold Start |
Yes |
Output pulse mode |
CW/CCW, Pulse/Direction, 90°/Ø difference output |
Servo motor I/F |
Yes |
Encoder input (up to 4x) |
Yes (A, B, & Z) |
Zero return command with encoder Z phase |
Yes (provided for each axis) |
General-purpose I/O terminal |
Yes (8 points for each axis) |
S-curve acceleration/deceleration control |
Yes |
Specify S-curve range |
Yes |
Triangle operation correction function |
Yes |
Operation mode selection |
Yes |
Pulser input |
Yes |
Comparator |
Yes (2 circuits for each axis) |
Pre-buffer for next operation |
Yes (primary) |
Next operation auto start control |
Yes |
Simultaneous start/stop |
Yes |
Interrupt status (interrupt cause monitor) |
Yes |
Specify interrupt cause |
Yes |
Interpolation operation |
Yes |
Continuous interpolation operation |
Yes |
Target position override |
Yes |
Operation switch input terminal |
Yes |
Synchronization signal output |
Yes |
Counter hardware latch |
Yes |