Number of control axes |
1 |
Reference clock (standard) |
19.6608MHz |
Maximum pulse output frequency |
4.9Mpps |
Number of speed setting registers |
2 (FL, FH) |
Number of steps to set/change the speed |
1 to 32,767 (15-bits) |
Speed multiplication rate range |
0.1 to 150x |
Acceleration range |
1 to 65,535 (16-bits) |
Deceleration rate range |
1 to 65,535 (16-bits) |
Number of positioning pulses |
0 to 268,435,455 (28-bits) |
CPU Interface |
8/16-bit bus |
Ramping down point |
0 to 16,777,215 (24-bits) |
Package types |
64-pin QFP |
Power supply voltage |
+5V ±5% |
Automatic ramp-down point setting |
Yes |
Ramp-down point offset setting |
Yes |
Up/down counter (Current position counter) |
Yes (28-bits) |
Up/down counter zero return |
Yes |
External mechanical signal input (±EL ±SD ORG) |
Yes |
External mechanical start signal for a Hold Start |
Yes |
Output pulse mode |
CW/CCW, Pulse/Direction |
Servo motor I/F |
Yes |
Encoder input (up to 4x) |
Yes (A, B, & Z) |
Zero return command with encoder Z phase |
Yes |
General-purpose I/O terminal |
Yes (11 points) |
S-curve acceleration/deceleration control |
Yes |
Specify S-curve range |
Yes |
Triangle operation correction function |
Yes |
One pulse output |
Yes |
Idling pulse |
Yes (0 to 7 pulses) |
Operation mode selection |
Yes |
Pulser input |
Yes |
Comparator |
Yes (2 circuits) |
Pre-buffer for next operation |
Yes (primary) |
Next operation auto start control |
Yes |
Micro step driver function |
Yes |
Output pulse length control |
Yes |
Simultaneous start/stop |
Yes |
Interrupt status (interrupt cause monitor) |
Yes |
Specify interrupt cause |
Yes |
Stepper motor out-of-order detection |
Yes |
Dummy operation (machine lock) |
Yes |
Continuous interpolation operation |
Yes |